Comtech EF Data TRP500 User Manual
Page 77
TRP500-4450 C-Band Outdoor Amplifier
REVISION 1
Appendix B
MN-TRP500
B–11
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Concise Alarm
Status
N/A 44
bytes
Query only.
Used to Query the Alarm status of the unit, response
is semicolon delimited. This is the concise version of
the RAS command.
Example:
CAS=a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;’cr’’lf
’
where: a thru z = 0, 1, 2, 3, 4, or 5
0 = FT, 1 = OK, 2 = AL, 3 = NO, 4 = YS, 5 = MS
a = +24V Power Supply
b = +24V Switch Power Supply
c = +13.5V Power Supply
d = +10V Power Supply 1
e = +10V Power Supply 2
f = +10V1 Amplifier Power Supply
g = +10V2 Amplifier Power Supply
h = +7.8V Power Supply
i = +5.8V Power Supply
j = +2.5V Power Supply
k = +1.2V Power Supply
l = -5.8V Power Supply
m = Fan#1 State
n = Fan#2 State
o = Fan#3 State
p = Heatsink Temp
q = Overtemp Shutdown
r = llC Status
s = Forward Power Alarm
t = Reverse Power Alarm
u = Flash Checksum
v = FPGA Done
w = Redundant Switch Condition
x = Redundant Link Status
y = Terminal Status Change
CAS= CAS?
CAS=x….x
(See description
for details of
arguments)