MD2401 L-Band Multi Demod Installation and Operation Manual

User Interfaces

MN-MD2401

4–40

Revision 7

Opcode: <2A17h>

Command a Demodulator’s Operating Mode

<1>

Operating Mode

0 = Stop, 1 = 2047 Test


Opcode: <2A1Ah>

Command a Demodulator’s BER Exponent

<1>

BER Measure
Period

Number of Bits in Measurement Period in Powers of Ten (ex:
6 = 10

6

Bits)


Opcode: <2A1Ch>

Command a Demodulator’s Terrestrial Loopback

<1>

Rx Terrestrial
Loopback

0 = Disabled, 1 = Enabled


Opcode: <2A1Dh>

Command a Demodulator’s Baseband Loopback

<1>

Rx Baseband
Loopback

0 = Disabled, 1 = Enabled


Opcode: <2A20h>

Command Center Buffer (No Parameters)


Opcode: <2A21h>

Command a Demodulator’s Data Invert

<1>

Data Invert

0 = Normal, 1 = Inverted


Opcode: <2A31h>

Command a Demodulator’s Buffer Size

<4>

Buffer Size

Byte 1 - 2 = buffer size in ms OR Byte 3 - 4 = buffer size in
bytes (Either ms or bytes must be specified - the other field
should be 0xFFFF)