• In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan."
• In Norway: “Apparatet må tilkoples jordet stikkontakt.”
•
In Sweden: “Apparaten skall anslutas till jordat uttag.”
Fuses
CAUTION
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH
THE CORRECT TYPE AND RATING.
The MD2401 contains no fuses:
Environmental
The MD2401 must not be operated in an environment where the unit is exposed to precipitation;
condensation; humid atmospheres above 95% RH; altitudes (unpressurized) greater than 2000
metres; excessive dust or vibration; flammable gases, corrosive or explosive atmospheres; or
extremes of temperature outside the ambient range 0 to +50°C. Maximum storage temperature
allowed is -25 to +85°C.
Operation in vehicles or other transportable installations that are equipped to provide a stable
environment is permitted. If such vehicles do not provide a stable environment, safety of the
equipment to EN 60950 may not be guaranteed.
Installation
PROPER GROUNDING PROTECTION IS REQUIRED – REFER TO THE
GROUNDING ‘CAUTION’ NOTE PROVIDED ON THE PREVIOUS PAGE. The
MD2401 is designed for connection to a power system that has separate ground,
line and neutral conductors. The equipment is not designed for connection to a
power system that has no direct connection to ground.
The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.
The MD2401 is shipped with a line inlet cable suitable for use in the country of operation. If it is
necessary to replace this cable, ensure the replacement has an equivalent specification. Examples
of acceptable ratings for the cable include HAR, BASEC and HOXXX-X. Examples of
acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC, NEMKO,
DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV.