beautypg.com

Specifications – AMETEK MX CTSH User Manual

Page 129

background image

User Manual

MX Series CTSH Compliance Test System

15. Specifications

15.1

About This Chapter

This chapters provides the technical specifications of the MXCTS measurement system and the
Power Analysis and Conditioning System unit (PACS-3-75). If the CTS system you have includes
an AC power source, refer to the separate AC source user manual that shipped with the AC
source.

Note:

All specifications listed in the manual are valid at an ambient temperature of 23° ± 5° and
apply after a 15-minute warm-up period.

15.2

PACS-3-75 Measurement Specifications

The MXCTS measurement system is implemented using a high speed Analog to Digital PCI plug in
board. This board needs to be installed properly in order to function according to the specification
listed here.

Measurement

Specification

Unit

Bandwidth

Anti Aliasing

Bandpass ripple

> 60 dB at 5 KHz

< 2 % up to 2.5 KHz

%

Volts

Range

0.01 - 312.00

V

rms

Max. input

1000

V

peak

Max. crest factor

5:1

Accuracy

± 0.1 % ± 0.05 % FS ± 3 mV

mV

Resolution

10

mV

Voltage CMRR

80

dB

RMS Current

Current ranges (Auto ranging)

16, 40, 75

A

rms

Highest range

75.00

A

rms

Max. input [permanent, no damage if
< 200 A

peak

] PACS-3-75

75.00

A

rms

Max. Crest Factor at max current [75
A Range]

2.5:1

Max. Crest Factor [Low Range]

20:1

Accuracy

± 0.1 % ± 0.05 % FS ± 5 mA

mA

Resolution

1

mA