ciLxs_ConfigureTriggeredSlewFrequency


ViStatus ciLxs_ConfigureTriggeredSlewFrequency
(ViSession instrumentHandle,
ViReal64 triggeredSlewFrequencyRate);

Purpose

This function configures the rate at which frequency changes for all
programmed changes in output frequency.


Parameter List

instrumentHandle

Variable Type ViSession

The ViSession handle that you obtain from the ciLxs_init or
ciLxs_InitWithOptions function. The handle identifies a particular
instrument session.

Default Value: None


triggeredSlewFrequencyRate

Variable Type ViReal64

Pass the rate at which frequency changes during a triggered output
transient. Instantaneous frequency changes can be obtained by sending
maximum or infinity. The driver sets the
CILXS_ATTR_TRIGGERED_SLEW_FREQUENCY_RATE attribute to this value.

Units: hertz per second


Valid Range: 0.0 to 9.9e37

Default Value: 9.9e37

NOTE:

If passed value is lower than zero then instrument will set maximum
possible range (INFinity).


Return Value

Returns the status code of this operation. The status code either
indicates success or describes an error or warning condition. You
examine the status code from each call to an instrument driver
function to determine if an error occurred.

To obtain a text description of the status code, call the
ciLxs_error_message function. To obtain additional information about
the error condition, call the ciLxs_GetError function. To clear the