IVI Driver Manual

Lx / Ls Series

97

Units: volts

Valid Range:
0.0 to 300.0 (for sinewave)

Default Value: 0.0 volts

Note:

1) You cannot program a voltage that produces a higher volt-second on
the output than a 300V rms sinewave.

2) The maximum peak voltage that the AC source can output is 425 V
peak. This includes any combination of voltage and function shape
values. Therefore, the maximum value that can be programmed depends
on the peak-to-rms ratio of the selected waveform. For a sinewave,
the maximum voltage that can be programmed is 300 V rms.



Return Value

Returns the status code of this operation. The status code either
indicates success or describes an error or warning condition. You
examine the status code from each call to an instrument driver
function to determine if an error occurred.

To obtain a text description of the status code, call the
ciLxs_error_message function. To obtain additional information about
the error condition, call the ciLxs_GetError function. To clear the
error information from the driver, call the ciLxs_ClearError
function.

The general meaning of the status code is as follows:

Value Meaning
-------------------------------
0 Success
Positive Values Warnings
Negative Values Errors

This driver defines the following status codes:

Status Description
-------------------------------------------------
ERRORS:
BFFA1001 The trigger source is not software trigger.

This instrument driver also returns errors and warnings defined by
other sources. The following table defines the ranges of additional
status codes that this driver can return. The table lists the
different include files that contain the defined constants for the
particular status codes:

Numeric Range (in Hex) Status Code Types
-------------------------------------------------
3FFA0000 to 3FFA1FFF IVI Warnings

This manual is related to the following products: