beautypg.com

Cilxs_configuretrigslewfrequencylist – AMETEK Ls Series Driver Manual User Manual

Page 120

background image

IVI Driver Manual

Lx / Ls Series

116

ciLxs_ConfigureTrigSlewFrequencyList


ViStatus ciLxs_ConfigureTrigSlewFrequencyList
(ViSession instrumentHandle, ViInt32 listSize,
ViReal64 _VI_FAR frequency[]);

Purpose

This function configures the sequence of frequency slew list points.

Parameter List

instrumentHandle

Variable Type ViSession

The ViSession handle that you obtain from the ciLxs_init or
ciLxs_InitWithOptions function. The handle identifies a particular
instrument session.

Default Value: None


listSize

Variable Type ViInt32

The number of list points.

frequency

Variable Type ViReal64[]

The sequence of frequency slew list points used to configure the AC
Source.

The frequency points are given in the command parameters, which are
separated by commas. The order in which the points are entered
determines the sequence in which they are output when a list is
triggered.

Units: HZ (Hertz) per second

Valid Range: 0.0 to 9.9e31

NOTE:

If passed value is lower than zero then instrument will set maximum
possible range (INFinity).



Return Value

Returns the status code of this operation. The status code either
indicates success or describes an error or warning condition. You
examine the status code from each call to an instrument driver

This manual is related to the following products: