ciLxs_ConfigurePhaseAngle
ViStatus ciLxs_ConfigurePhaseAngle (ViSession instrumentHandle,
ViChar _VI_FAR phase[],
ViReal64 angle);
Purpose
This function configures the phase of the output voltage waveform
relative to an internal reference.
Parameter List
instrumentHandle
Variable Type ViSession
The ViSession handle that you obtain from the ciLxs_init or
ciLxs_InitWithOptions function. The handle identifies a particular
instrument session.
Default Value: None
phase
Variable Type ViChar[]
Pass the virtual phase name that you assign to the instrument in the
Configuration Utility.
Virtual phase names are aliases for instrument-specific phase
strings. The instrument-specific phase strings can differ from one
instrument to another. Virtual phase names allow you to use and swap
instruments without having to change the phase names in your source
code. You assign a virtual phase name to an instrument-specific
phase through the Configuration Utility. This control accepts
virtual phase names you have assigned to the specific instrument you
are using. It also accepts the instrument-specific phase names.
Default Value: ""
Notes:
(1) You can specify the phase name as a string variable or as a
literal enclosed in double quotes.
angle
Variable Type ViReal64
Pass the phase of the output voltage waveform relative to an internal
reference. Positive phase angles are used to program the leading
phase, and negative phase angles are used to program the lagging