ciLxs_ConfigureSlewVoltageLevel


ViStatus ciLxs_ConfigureSlewVoltageLevel (ViSession instrumentHandle,
ViChar _VI_FAR phase[],
ViReal64 slewVoltageRate);

Purpose

This function configures the slew rate for all programmed changes in the
ac rms output voltage level of the AC source.

Parameter List

instrumentHandle

Variable Type ViSession

The ViSession handle that you obtain from the ciLxs_init or
ciLxs_InitWithOptions function. The handle identifies a particular
instrument session.

Default Value: None


phase

Variable Type ViChar[]

Pass the virtual phase name that you assign to the instrument in the
Configuration Utility.

Virtual phase names are aliases for instrument-specific phase
strings. The instrument-specific phase strings can differ from one
instrument to another. Virtual phase names allow you to use and swap
instruments without having to change the phase names in your source
code. You assign a virtual phase name to an instrument-specific
phase through the Configuration Utility. This control accepts
virtual phase names you have assigned to the specific instrument you
are using. It also accepts the instrument-specific phase names.

Default Value: ""

Notes:

(1) You can specify the phase name as a string variable or as a
literal enclosed in double quotes.


slewVoltageRate

Variable Type ViReal64

Pass the slew rate for all programmed changes in the ac rms output
voltage level of the AC source. The driver sets the
CILXS_ATTR_SLEW_VOLTAGE_RATE attribute to this value.

Units: volts per seconds