AMETEK Compact IX 2253 User Manual
Page 90

User Manual
2253i / 2253iX
AMETEK California
Instruments
90
4.8 Setting the Power-on Initialization Values
The power source is shipped with default factory settings when the unit is powered up. The factory
settings are:
Parameter
Factory default setting
Voltage 0.0
Volt
Voltage Range
150 Volt Range
Frequency 60
Hz
Current limit
Maximum available current for selected V Range.
Output state
OFF
Local / Remote State
Local. Front panel unlocked.
Table 4-3: Factory Default Power on Settings
It is possible to change the power on initialization values in one of two ways:
1. Using the IEEE-488, LAN or USB bus interface.
2. Using the front panel.
To change the power on initialization values from the front panel, proceed as follows:
1. Set the AC power source output parameters from the front panel as you want to power up the
unit.
2. Save this setting to setup register 0 from the REGISTERS menu.
3. Select the CONFIGURATION menu and move to the POWER ON field.
4. Change the POWER ON field to REG0.
5. This will recall the settings contained in register 0 at power up.