9 ext option - supplemental specifications – AMETEK Compact IX 2253 User Manual
Page 29
User Manual
2253i / 2253iX
AMETEK California
Instruments
29
20 KOhm.
This option is mutually exclusive with the –LKS and –EXT option.
-WHM
Watt-hour measurement option.
2.9 EXT Option - Supplemental Specifications
When the EXT option is installed, the amplifier is used in an open loop mode and none of the regular compact iX
Series output specifications apply. This option also precludes the presence of the –RPV and –RPF option.
An external signal input is provided for each phase. The phase A EXT input pins is also used on the Auxiliary I/O
connector for the RPVA option so the RPV and EXT options are mutually exclusive. The voltage reference (VOLT
REF) on the CONTROL screen of the power source controller must be set to EXT to use this feature. See section
8.4 for EXT option operating instructions.
Parameter
Supplemental Specification
Input:
Isolated inputs, RPVA, EXTB, EXTC to analog common inputs on DB15
Auxiliary I/O (J18)
Level 0 – 5 Vrms / -7.5 Vpk to +7.5 Vpk max. for 0 to 300Vrms. (Gain = 35.6 dB)
Voltage range is fixed to 300V AC range.
Impedance < 4 KOhm
Output:
0 – 300 Vac RMS
Allowable Frequency:
Range 16 – 1000 Hz
Freqeuncy Response
See Figure 2-7.
Phase Phase offsets determined by provided external signal inputs A, B, C.