2253i / 2253iX

AMETEK California

Instruments

121


T1





0 Volt

F1

F2



T2

T3




Test no.:

21

22

23

24

25

26

Standard:

I

II

III

IV

V

VI

T1

(ms)

50 50 100 100 200 200

F1

(Hz) 360 Fmax 360 Fmax 360 Fmax

F2

(Hz)

Fmax 360 Fmax 360 Fmax 360

Fmax = 650 Hz for Group2/A(NF)
Fmax = 800 Hz for Group3/A(WF)
T2 = 20 msec
T3 = 5 msec

Figure 9-7: Power Interrupt for Group2/A (NF) and Group3/A(WF)

VOLTAGE SURGE

This test requires 160V output voltage. If the power source is set at the low voltage range, the high
voltage range will be selected before the test starts. At the end of the test, the power source will be
switched back to the low range automatically.

Voltage

Time

Seq. No.

RTCA

Group 1

Group 2

Group 3

ALL

1

115 115 115 115

5

Minute

2

160 160 160 170

30msec

3

115 115 115 115

5

Sec.

4

60 70 70 70

30msec

5

115 115 115 115

5

Sec.

Table 9-5: Normal VoltageSurge Sequence

The output voltage will follow the sequence in Table 9-5. The above sequence will repeat itself three
times. Each repeat will start from sequence two. RTCA and Group 1 will run at 400 Hz. Group 2 and
A(NF) will run at 360 Hz and 650 Hz. Group 3 and A(WF) will run at 360Hz and 800Hz. The
frequency will return to the nominal setting when the test is completed. The BACK key (backspace)
will terminate the test at any time.