User Manual

2253i / 2253iX

AMETEK California

Instruments

32

2.13 Supplemental Specifications

Supplemental specifications are provided for reference only and are not guaranteed. Data is based on
typical performance of a Compact i/iX series power source but not verified on each unit produced as
part of AMETEK Programmable Power acceptance test.

Results on individual units may vary from the data provided here.

2.13.1 Output

Output Parameter

Specification

Frequency response:

See

Figure 2-8

Max. Voltage slew:

4V/us, measured step response into resistive load, 10% to 90 % full-

scale voltage.

Load Transient response

No load to full load:

Voltage recovers to within 2% in less than 2 ms

Full load to no load:

Voltage recovers to within 2% in less than 2 ms

Load Regulation response in
ALC mode

< 300 ms

Load Regulation:
(ALC mode OFF)

< 3 % FS

1

Figure 2-8: Typical frequency response, low Vrange, ALC off.

1

FS (Full Scale) refers to highest available range, e.g. 300Vac in AC mode, 400Vdc in DC mode.