Optimize_multi_corner_timing – Altera Quartus II Settings File User Manual
Page 655
OPTIMIZE_MULTI_CORNER_TIMING
Controls whether the Fitter optimizes a design to meet timing requirements at all process corners and
operating conditions. The Optimize Timing logic option must be enabled for this option to work. When
this setting is turned off, designs are optimized to meet timing only at the slow timing process corner and
operating condition. When this option is turned on, designs are optimized to meet timing at all corners
and operating conditions; as a result, turning on this option helps create a design implementation that is
more robust across process, temperature, and voltage variations.\r\n\r\nTurning on this option does not
enable multi-corner timing analysis. To enable multi-corner timing analysis, see the TimeQuest Timing
Analyzer page of the Settings dialog box.
Old Name
OPTIMIZE_FAST_CORNER_TIMING, Optimize Fast-Corner Timing
Type
Boolean
Device Support
This setting can be used in projects targeting any Altera device family.
Notes
This assignment is included in the Fitter report.
Syntax
set_global_assignment -name OPTIMIZE_MULTI_CORNER_TIMING
MNL-Q21005
2015.05.04
OPTIMIZE_MULTI_CORNER_TIMING
655