beautypg.com

Async_pipeline_disable_destination_check – Altera Quartus II Settings File User Manual

Page 438

background image

ASYNC_PIPELINE_DISABLE_DESTINATION_CHECK

Allows the Automatic Asynchronous Signal Pipelining algorithm to run on the specified asynchronous

signal even if it feeds synchronous inputs. However, turning this option ON can change circuit

functionality. This option is intended for advanced users

Type

Boolean

Device Support

This setting can be used in projects targeting any Altera device family.

Syntax

set_global_assignment -name ASYNC_PIPELINE_DISABLE_DESTINATION_CHECK -
entity
set_instance_assignment -name ASYNC_PIPELINE_DISABLE_DESTINATION_CHECK -to
-entity

438

ASYNC_PIPELINE_DISABLE_DESTINATION_CHECK

MNL-Q21005

2015.05.04

Altera Corporation

Quartus Settings File Reference Manual

Send Feedback