Fit_attempts_to_skip – Altera Quartus II Settings File User Manual
Page 554
FIT_ATTEMPTS_TO_SKIP
Controls how many fit attempts the Fitter skips. In subsequent fit attempts, the Fitter uses higher effort to
improve design routability at the expense of longer compilation times. Use this setting to force the Fitter
directly into a second or third fit attempt, which will save time when it is known that multiple attempts
are needed. This setting causes the same amount of additional effort to be applied but does not guarantee
an identical result to what would be achieved if all fit attempts were performed. For some families, the
Fitter will not perform a third fit attempt automatically due to the long compilation time and possible
timing quality degradation. However, a third fit attempt can still be forced to run by setting this value to 2.
Type
Integer
Device Support
This setting can be used in projects targeting any Altera device family.
INTEGER_RANGE
0, 0
Notes
This assignment is included in the Fitter report.
Syntax
set_global_assignment -name FIT_ATTEMPTS_TO_SKIP
Default Value
0.0
554
FIT_ATTEMPTS_TO_SKIP
MNL-Q21005
2015.05.04
Altera Corporation
Quartus Settings File Reference Manual