Kipp&Zonen BSRN Scientific Solar Monitoring System User Manual
Page 75
63
Field
Param eter
Description
Explanation
1
Num ber of Instrum ents
num eric value of num ber of
instrum ents supplying data
m ore than one instrument m ay be supplying
the transm ission data
2
Instrum ent #1 Type
num eric key defining type of
instrument
direct pointing (1), cosine derived (2)
3
Instrum ent Description
Text description of instrum ent
Manufacturer, model, serial num ber (if
applicable), general inform ation on method
of observation, data collection, etc.
4
Detector Type
Text description of the detector
The type of detector (e.g., photodiode,
PMT, single, array). The manufacturer and
m odel of detector used (if known). If m ore
than one type of detector is used indicate
the detector/wavelength pairing
5
Optics Type
Text description of the instrument
optical train.
Description of optics (e.g., single detector
with filter wheel; m ultiple detectors with
m ultiple entrance apertures; focussed
system ; grating; prism ; etc.)
6
Field of View
Param eters
Num eric parameters based on
type of optics
Inform ation such as opening angle, slope
angle, f-num ber for focussing instrum ents,
directional responsivity for cosine-type
instrum ents, etc.
7
Num ber of
wavelengths
Num eric value of the num ber of
wavelengths
Multiple wavelengths are possible from
each instrument
8
Calibration method
Num eric key indicating type of
calibration
Langley (1), Instrum ent com parison (2),
standard lam p (3), trap detector (4),
com bination or other (5)
9
Calibration description
Text description of calibration
m ethod
Detailed inform ation on method of
calibration
10
Calibration date
Date of calibration. Date to be
given in same form at as
broadband calibrations.
The calibration date given m ay not be the
m ost recent calibration.
11
W avelength #1
Actual wavelength (8)
The measured central wavelength of the
passband (e.g., 501.2 nm , not 500 nm )
12
Bandpass #1
W idth of first bandpass (*8)
Measured FW HM of bandpass
13
Description of
bandpass #1
Text description of bandpass
Inform ation on filter function, blocking filters,
slit function etc., depending on type of
instrument
14
Calibration uncertainty
for wavelength #1
Num eric parameters that describe
the uncertainty of the calibration
procedure
Include the com bined uncertainty of all
aspects of the calibration and the
confidence level
15
Repeat fields 11 - 14
for each w avelength
16
Repeat fields 2 - 15
for each instrum ent
Table 7.3. Inform ation required by the archive on the instrum ent(s) being used for determ ining
atm ospheric transm ission.