beautypg.com

Scpi management errors (system errors) – EXFO FLS-2600B Tunable Laser Source User Manual

Page 143

background image

Remote Control

Tunable Laser Source

135

SCPI Management Errors (System Errors)

SCPI Management Errors (System Errors)

Error

Number

Description

Probable Cause

–100

Command error

The SCPI Manager does not

recognize the command, probably

due to invalid module address.

104

Data-type error

A data parameter is not the

expected data type.

108

Parameter not allowed

Too many parameters were

detected for the specified

command.

109

Missing parameter

A required parameter was not

detected.

113

Undefined header

The SCPI Manager does not

recognize the command, probably

due to incorrect grammar.

130

Suffix error

An error occurred while parsing a

suffix.

131

Invalid suffix

The suffix does not follow the

appropriate syntax or is
inappropriate for this device.

138

Suffix not allowed

A suffix was encountered after a

numeric element that does not

allow suffixes.

200

Execution error

An error occurred while executing

the command.

222

Parameter out of range

The Tunable Laser Source has

received a data parameter outside

the valid range.