Source:sweep:continuous:program – EXFO FLS-2600B Tunable Laser Source User Manual

Page 127

background image

Remote Control

Tunable Laser Source

119

Programming Commands

Note

You cannot use this command while the FLS-2600B is performing

a sweep.
You do not have to enter all values in the command, but you must

enter the values in the same order as in the Syntax section. If you

want to enter only some of the values, use a comma ( , )

to separate the values, including the ones you did not enter.
For each value including units, such as wavelengths or speed,

you can specify a unit to use in the same way as the specific

commands in the previous pages. If you do not specify the units,

the system will use those that are currently set.
To specify the units, add at the end of the value

you want to modify. The parameter will be a wavelength

unit (nm or THz) or a speed unit (nm/s or THz/s).

Examples

A complete command:
SOUR:SWE:CONT:PROG 1550.50,1600.50,10.000,25,1,1
A command changing only the speed and reverse options:
SOUR:SWE:CONT:PROG ,,10.000,,0,
A command setting the start and stop wavelengths in THz, as

well as the speed in THz/s, leaving the latter at its original

settings:
SOUR:SWE:CONT:PROG 196.7 THZ,186.8 THZ,5.000 THZ/S

SOURce:SWEep:CONTinuous:PROGram