Toa D-2000 Series Installation User Manual
Page 7
7
1. Power switch [POWER ON/OFF]
Power is switched on and off with each
depression of this switch.
2. Power lamp
Lights when the power switch is set to ON.
3. Monitor number
Number of channel to be monitored using
headphones.
4. Level indicators [PEAK, +12 dB, 0 dB, –40 dB]
Indicate the signal level of each individual
channel.
Indicate the PFL (pre-fader level) value for the
input channel, and the AFL (after-fader level)
value for the output channel.
When an output channel is muted, only the
PEAK indicator lights. When all output channels
are muted by the "All Mute" function, all the
PEAK indicators flash.
5. Gate indicator (Orange)
Lights when the gate* is activated.
* This function passes, attenuates, or cuts the
input signal depending on its signal level.
6. Monitor selection indicator (Orange)
Lights to indicate the corresponding channel is
selected for monitoring using headphones.
7. Key lock indicator (Red)
Lights when key lock function is enabled.
8. Item selection indicators [PRESET, UNIT ID,
MONITOR, CONSOLE, CobraNet] (Green)
The indicator of the item selected with the
Selection keys (14) lights.
9. Number display
Displays the number of the preset memory
recalled.
10. Reset switch
Restarts the D-2008SP when pressed.
Press the switch (recessed) with a pen tip.
Note
Reactivating the unit stops audio signals
currently being output.
11. USB terminal
Not used.
12. Headphone jack
Audio outputs for the channel of which Monitor
selection indicator (6) is lighting can be
monitored. Connect stereo headphones of 16 Ω
or more. Adjust the monitor volume with the
headphone volume control knob (13).
13. Headphone volume control knob
Adjusts the headphone volume.
14. Selection keys
Use the Up and Down keys to select the Item
selection indicator.
Use the Left and Right keys to select the preset
memory number when recalling the preset
memory or the desired monitor number when
MONITOR is selected.
15. Set key
Used for preset memory recall or key lock
setting.
16. LAN LINK/ACT indicator (Green)
Lights when the LAN connector on the rear panel
is connected, and flashes during LAN
communications.
17. LAN DETECT indicator (Orange)
Lights when this unit is selected on the D-2000
Setting Software.
18. SYSTEM STATUS indicator (Green)
Lights when the unit is in communication with a
PC.
19. SYSTEM ERROR indicator (Red)
Lights while the unit is being activated, and goes
out after the activation has been completed.
If this indicator remains lit even after activation
completion, this indicates an internal fan failure.
(For the relationship between the indicator and
D-2008SP status, refer to the table on p. 8.)
20. SYSTEM RUN indicator (Green)
Lights when the unit is in normal operation, and
goes out when a failure occurs.
(For the relationship between the indicator and
D-2008SP status, refer to the table on p. 8.)
21. CobraNet PRIMARY LINK indicator (Green)
Flashes during CobraNet communications via
the primary port.
22. CobraNet SECONDARY LINK indicator
(Green)
Flashes during CobraNet communications via
the secondary port.
23. CobraNet CONDUCTOR/PERFORMER
indicator (Green)
Flashes when the primary port is in operation as
the conductor, and lights when it is in operation
as the performer.
24. WORD CLOCK SYNC indicator (Green)
Lights when internal word clock synchronization
is stable. Goes out if the clock gets out of
synchronization, then the internal mute functions,
causing the audio outputs to be interrupted. Even
if once the clock had got out of synchronization,
when the internal clock has stabilized, such
operation state automatically returns to normal.