7. Level indicators [PEAK, +12 dB, 0 dB, –40 dB]
Indicate signal levels for each channel. Pre-fader
value is indicated for input channels and post-
fader value for output channels. Adjust the sound
volume so that the Peak indicator does not
continuously remain lit.
8. Monitor channel selector keys
Select the channel to be monitored. Pressing a
key causes it to light and allows its
corresponding channel to be monitored. Pressing
the key again causes the light to go out,
disabling monitoring.
It can be enabled to switch the D-2008SP's
selection channel on the D-2000 Setting
Software in synchronization with this key
operation. (For details, read the separate Setting
Software Instructions, "Console SEL/MONI key
interlock setting.")
9. Channel ON/OFF keys
Turn on or off the output for each channel.
Pressing a key causes it to light and the signal of
its corresponding channel to be output. When
pressed again, the light goes out and the
channel's signal output is stopped.
10. Write-in space
Write the name of the input or output channel,
etc. in these spaces.
11. Motorized faders (1 – 12)
Adjust the volume of each input or output
channel. With reference to fader position "0," the
position "–∞" provides the minimum volume, and
position "+10" the maximum volume.