Caution – Toa D-2000 Series Installation User Manual
Page 29
29
3.2. Rack Mounting
D-2008SP
D-2008SP
Perforated panel
(with ventilation slots)
Notes
• To achieve sufficient ventilation, be sure to mount a perforated panel larger than 1U size* above and below
the unit.
• Do not position the heat-generating component such as a power amplifier immediately below the D-2008SP
in the rack even if the perforated panel is mounted between them. Also, keep such components away from
each other so that the ambient temperature around the D-2008SP should not exceed +40 ºC (104 ºF).
Failure to do so may shorten the product life.
* 1U size = 44.5 mm or 1.75" (standard size)
3.2.1. D-2008SP
(When rack mounting screws are supplied)
The supplied rack-mounting screws can be used for the TOA equipment
rack only. Do not use them for other racks.
When installing the unit in a rack other than that of TOA, be sure to use
the screws with a diameter of over 5 mm (0.2") and length of over 12 mm
(0.47") to mount the unit.
Failure to do so may cause personal injury.
(When rack mounting screws are not supplied)
Rack mounting screws are not supplied with the unit.
Be sure to use the screws with a diameter of over 5 mm (0.2") and length
of over 12 mm (0.47") to mount the unit.
Failure to do so may cause personal injury.
CAUTION