beautypg.com

Toa D-2000 Series Installation User Manual

Page 37

background image

37

4.5. Audio Monitor Line Connection When Multiple Units Are Connected

Connecting multiple D-2008SP units through monitor input and output terminals allows audio signals other
than that of the main unit to be monitored.

[Connection Example]

D-2008SP
(ID1)

Slot 8

Slot 1

3

4

5

Slot 8

Slot 1

5

Slot 8

Slot 1

7

Slot 3: D-2000DA1
Slot 4: D-2000DA1
Slot 5: D-2000AD1

Slot 5: D-2000AD1
Slot 8: D-2000DA1

Slot 7: D-2000AD1

D-2012C (ID 1)

Note:

D-2008SP
(ID 2)

D-2012C (ID 2)

D-2012C (ID 3)

D-2008SP
(ID 3)

Speaker

Power amplifier

Switching hub

Audio signals of the
D-2008SP units with
ID1 and ID2 only can
be monitored

Note: Audio signals of the

D-2008SP units with
ID1 and ID3 only can
be monitored.

Note: Audio signals of the

D-2008SP units with
ID1 through ID3 can
be monitored.

Monitor bus

Monitor bus

Monitor bus

Monitor output 1

Monitor input

Monitor input

Monitor input

Monitor input

Monitor output 1

Monitor output 2

Monitor output 2

Notes
• Set the identical ID number for the D-2008SP and D-2012C to be connected through monitor bus terminals.

Use the D-2000 Setting Software to set the ID number.

• Insert the audio module used for monitor input into one of Slots 5 – 8.
• Neither the D-936R Stereo input module nor D-937SP Digital input module can be used as a monitor input.
• When using the D-922F and D-922E Microphone/Line input module as monitor inputs, set the "PHANTOM"

switch to "OFF" and "Input sensitivity" to "+4 dB (LINE)."

• The headphones connected to the D-2008SP can only monitor audio signals from the channels of this D-

2008SP.