beautypg.com

Alarm input port, Alarm output port – IC Realtime Flex Series: 32-CH High Performance H.264E 2U DVR User Manual

Page 35

background image

25

485 A/B

485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.


3.8.2 Alarm Input Port

Please refer to the following sheet for more information.
 Normal open or Normal close type.
 Please parallel connect COM end and GND end of the alarm detector ( Provide external

power to the alar m detector).

 Please parallel connect the Ground of the DVR and the ground of the alarm detector.
 Please connect the NC port of the alarm sensor to the DVR alarm input(ALAR M)
 Use the same ground with that of DVR if you use external power to the alarm device.

Figure 3-3

3.8.3 Alarm Output Port

 Provide power to peripheral alarm device.
 To avoid overloading, please read the following relay parameters sheet carefully.
 RS485 A/B cable is for the A/B cable of the PTZ decoder.

Relay Specification

M odel:

JRC-27F

Mater ial of the
touch

Silver

Rating
(Resistance
Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between touches with same
polarity

1000VAC 1minute

Between touches with different
polarity

1000VAC 1minute

Between touch and winding

1000VAC 1minu te

Surge voltage

Between touches with same
polarity

1500V (10×160us)

Length of open
time

3ms max

Length of close
time

3ms max