EVCO EVF328J9 User Manual
Page 41

EVCO S.p.A.
EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114
Page 41 of 62
c0
0
1
- - -
0
not dis.
enabling the restriction between the power distributed at
the top (Po1) and the power distributed at the floor
(Po2)
1 = YES - setting the power distributed at the top
causes automatic adaptation of the power
distributed at the floor (and vice versa), such to
guarantee that the sum of the two power values
is always 100
c1 1 999 s 80 80
if CFG = 0, cycle time for switch-on of the top output
and the floor output,; see also Po1 and Po2
if CFG = 1, cycle time for switch-on of the top output
and the floor output during the "energy saving" function
(5)
c2
0
1
- - -
0
not dis.
activation of the "quick heating" function at device
switch-on
1 = YES
c3 0 999
°C/°F
(1)
150
not
dis.
temperature of the chamber above which the " quick
heating" function is interrupted
c4 -1 120 s
15 15
duration of the activation of the buzzer on conclusion of
the cooking timer count (6)
-1 = the buzzer must be silenced by pressing and
releasing the key
c5 0 60 min 20 20
vent activation advance on conclusion of the cooking
timer count; see also c6
c6
0
60
min
20
20
duration of vent activation from advance c5
c7
0
60
min
30
30
maximum duration of vent activation in manual mode
c8
0
1
- - -
1
1
time shown on the bottom part of the "UPPER" display
when the device is off
1 = YES
c10
0
240
min
120
120
maximum duration of the "energy saving" function (7)
c12 0 240 min 60 60
time that must pass in absence of operations on keys
(from device switch-on due to effect of the "weekly
programmed switch-on" function), until the function is
activated again
1 = YES
c13 0 100 % 50
not
dis.
percentage reduction of the switch-on durations of the
top output and the floor output during the "energy
saving" function