10
"WEEKLY PROGRAMMED
SWITCH-ON" FUNCTION
10.1
Preliminary notes
The “weekly programmed switch-on” function allows to
program device switch-on and simultaneously start a program;
see chapter
9
““PROGRAMS”
FUNCTION
”.
The function must be activated with the procedure illustrated
in paragraph 10.3 “Enabling the "
weekly programmed
switch‐on" function
”.
The cooking cycle must be started by pressing and releasing
the "START/STOP" key.
If parameter r12 is set at 0, the "weekly programmed switch-
on" function will not be available.
10.2
Setting the switch-on day and
time and the program to start
The switch-on day is displayed in the 1... 7
format (number 1 corresponds to Monday); the time is
displayed in the 24 h format (hours:minutes).
Operate as follows to set the switch-on day:
1.
Make sure that parameter r12 is set at 1, that
programs are used, that the device is off and that
no procedure is in progress.
2.
Hold the “PROGRAMS” key down for 1 s: the
“DELAY” LED will switch on and the bottom part
of the “UPPER” display will show the switch-on
day; the day value will flash.
If no switch-on time is set, the bottom part of the
"UPPER" display will only show the switch-on day.
3.
Press and release the UP or DOWN key within 15 s
to set the value of the day.
Operate as follows to set the program to start-up:
4.
Press and release the “PROGRAMS” key while
setting the switch-on day: the bottom part of the
“LOWER” display will show the number of the first
program used; the program number will flash.
If no program is used, the bottom part of the
“LOWER” display will show “-“ flashing.
5.
Press and release the UP or DOWN key within 15 s
to select the number of a program.
Setting the switch-on day and time and the program to start