5 setting the configuration parameters – EVCO EVF328J9 User Manual
Page 34

EVCO S.p.A.
EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114
Page 34 of 62
Operate as follows to set the power distributed at the floor:
6.
Ensure that the device is switched on and that no
other procedure is in progress.
7.
Press and release the "FLOOR" key twice: the
LED of the “LOWER” display will flash and the top
part of the display will show the flashing power
value.
8.
Press and release the "UP" or "DOWN" key within
15 s to set the power value, see also parameters
c0 and c1.
9.
Press and release the "FLOOR" key or do not
operate for 15 s: the
LED will switch off and
then the device will exit the procedure.
Operate as follows to exit the procedure before the operation
is complete:
10.
Do not operate for 15 sec (any changes will be
saved).
14.5
Setting the configuration
parameters
Operate as follows to access the procedure:
1.
Make sure there is no cooking cycle or any
procedure in progress.
2.
Hold the UP and DOWN key for 4 s: the top part of
the “UPPER” display will show“PA”.
3.
Press and release the “TOP” key or the “FLOOR”
key: the “LOWER” part of the display will show
“0”.
4.
Press and release the “DOWN” key within 15 s to
set “-19”.
5.
Press and release the “TOP” key or the “FLOOR”
key or do not operate for 15 s.
6.
Hold the "UP" and "DOWN" key for 4 s:
-
in the event of operation with an
analogue input, the top part of the
“UPPER” display will show “SP”
-
in the event of operation with two
analogue inputs, the top part of the
“UPPER” display will show “SP1”
Operate as follows to select a parameter:
7.
Press and release the “UP” key or the “DOWN”
key.
Setting the power distributed at the floor
Setting the configuration parameters