EVCO EVF328J9 User Manual
Page 10
![background image](/manuals/675278/10/background.png)
EVCO S.p.A.
EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114
Page 10 of 62
3
ELECTRIC CONNECTION
3.1
Electric connection
The following drawing illustrates the devices' electric connection.
The utility managed by the K4 digital output, depends on the configuration parameter u1, as follows:
-
extraction hood (parameter u1 = 0, factory setting)
-
multifunction (u1 = 1).
The utility managed by the K5 digital output, depends on the configuration parameter u11, as follows:
-
technical compartment fan (parameter u11 = 0, factory setting)
-
switch-on/off (u11 = 1).
For the settings relative to the configuration parameters, see chapter 14 “CONFIGURATION”.
The TTL port is the communication port with the EVKEY programming key.
The RS-485 port is the communication port with the following EVCO products:
-
parameters Manager set-up software system
-
device for recording data and to download recorded data (via USB) EVUSBREC01.
-
RICS plants monitoring and surveillance systems
The port must not be used simultaneously with more than one of these products.