evaporator fan

8 A

door heating elements/condenser fan

16 A

cabinet light/needle probe heating/UV light

8 A

Communication port

EVF815

serial port with MODBUS communication protocol

Other features

EVF815

protection rating of the user interface

IP65

clock

signal buzzer and alarm

direct loads connection

except for the utility managed by the fifth digital output

management of three types of backlight

management of blast chilling and storage/deep freezing
and storage cycles

management of temperature/time controlled operation
cycles

hard/soft operating cycles management

management of the test regarding correct insertion of
the needle probe

memorisation of the defrosting interval

management of temperature alarms

compressor operating hours count

“HACCP” function

"keyboard lock" function

configuration parameters access password

restoring the factory settings