beautypg.com

4electric connection, 1 electric connection – EVCO EVF815P9 User Manual

Page 13

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 13 of 60

4

ELECTRIC CONNECTION

4.1

Electric connection

The following drawing illustrates the EVF815 electric connection.

The utility managed by the K4 output, depends on parameter u1, as follows:

-

door heating elements (u1 = 0, pre-defined setting)

-

condenser fan (u1 = 1).

For the settings relative to the parameters, see chapter 9 “CONFIGURATION”.

The utility managed by the K5 output, depends on parameter u11, as follows:

-

cabinet light (u11 = 0, pre-defined setting)

-

needle probe heating (u11 = 1)

-

UV light (u11 = 2).

For the settings relative to the parameters, see chapter 9 “CONFIGURATION”.

The serial port is for the connection of the controller to the following additional products:

-

EVKEY programming key

-

Parameters Manager set-up software system

-

RICS plants monitoring and surveillance systems

-

Device for recording data, for downloading the data recorded (via USB), for uploading and downloading
EVUSBREC01 configuration parameters.

The port must not be used simultaneously with more that one of these products.