beautypg.com

14 technical data, 1 technical data – EVCO EVF815P9 User Manual

Page 54

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 54 of 60

14

TECHNICAL DATA

14.1

Technical data

Purpose of the device:

blast chiller controller.

Execution:

user interface

control module

board without cover behind a
Plexiglas sheet.

board without cover.

Dimensions:

user interface

control module

290.0 x 50.5 x 38.0 mm
(11.417 x 1.988 x 1.496 in;
L x H x P).

99.0 x 108.0 x 24.0 mm (3.897
x 4.251 x 23.978 mm; L x H x
D).

Installation:

user interface

control module

rear of panel, with biadhesive
tape.

on flat surface, with spacers.

Protection rating:

user interface

control module

IP65. IP00.

Connections:

user interface

control module

fixed screw terminal boards
(control module).

fixed screw terminal board
(user interface and inputs), 6.3
m faston (0.248 in, power
supply and outputs), 6 pole
connector (serial port).

The maximum length of the user interface
-control module connection is 20 m (65.614 ft).

Temperature of use:

from 0 to 55 °C (from 32 to 131 °F).

Storage temperature:

from -25 to 60 °C (from -13 to 140 F).

Humidity for use:

from 10% to 90% relative humidity without condensate.

Pollution situation:

2.

Power supply:

user interface

control module