beautypg.com

EVCO EVF815P9 User Manual

Page 33

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 33 of 60

r17 0.0 99.0 °C/°F

(1) 5.0

"temperature detected by the needle probe - cabinet
temperature" minimum difference such to consider the first
phase of the test to verify correct insertion of the needle
probe completed successfully (consider the difference
without sign)
0.0 = the test will not be performed (neither first or second

phase)

r18 1 99

s

60

duration of the second phase of the test for verification of
correct insertion of the needle probe

r19

0

1

- - - -

0

quick modification value during the "On" status before
starting the operating cycle
0 = work set-point during blast chilling or during deep

freezing

1 = blast chilling or deep freezing end temperature

r20

0

1

- - - -

1

memorisation of the quick modification value during the
"On" status before starting the operating cycle
0 = no (on start-up of the successive same cycle, the

values established with parameters r7 and r3 or
those establishes with r4 and r8 will be re-proposed)

1 = yes (on start-up of the successive same cycle the

rapidly modified values will be re-proposed before
starting the previous same cycle)

r21

0

1

- - - -

1

modality the operating cycle is started time controller rather
than time controlled
0 = automatic (or through the test regarding correct

insertion of the needle probe)

1 = by hand (or pressing and releasing the BLAST

CHILLING or DEEP FREEZING key)

r22

0

1

- - - -

0

modality to start pre-cooling
0 = manual (or pressing the BLAST CHILLING key 1 s)
1 = both automatic (or passing from the "stand-by"

status to the "on", then switching on the device) and
by hand (or pressing the BLAST CHILLING key 1 s)

r23 0 50

s

2

duration of the buzzer activation to signal the verification
test for the correct insertion of the needle probe will not
have been completed successfully

Par.

Min.

Max.

Unit

Default

Compressor protections