5.5

Display of the temperature detected by the needle
probe

Operate as follows:
1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key down for 1 s: the display will show the first label available.

3.

Press and release the UP or DOWN key to select “Pb2”.

4.

Press and release the BLAST CHILLING key: the display will show the temperature detected by the needle
probe.

Operate as follows to exit the procedure:
5.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “Pb2” again.

6.

Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.

If the needle probe is not enabled, i.e. if parameter P3 is set at 0, the “Pb2“ label will not be displayed.

5.6

Evaporator temperature display

Operate as follows:
1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key down for 1 s: the display will show the first label available.

3.

Press and release the UP or DOWN key to select “Pb3”.

4.

Press and release the BLAST CHILLING key: the display will show the evaporator temperature.

Operate as follows to exit the procedure:
5.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “Pb3” again.

6.

Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The
display" or do not operate for 60 s.

If the evaporator probe is not enabled, i.e. if parameter P4 is set at 0, the “Pb3“ label will not be displayed.

5.7

Defrosting activation in manual mode

Operate as follows:
1.

Make sure the device is in the "on" status or a storage is in progress.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Hold the UP key down for 4 s: the LED will switch on.

If the evaporator probe is enabled, i.e. the parameter P4 is set at 1 and on activation of defrosting the evaporator
temperature is above that established with parameter d2, defrosting will not be activated.

5.8

Switch-on/off of the cabinet light in manual mode

Operate as follows:
1.

Make sure that parameter u11 is set at 0.

2.

Make sure no procedures are in progress

3.

Press and release the DEEP FREEZING key for 1 sec.: the AUX LED will switch on/off.