EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 31 of 60

P0

0

1

- - - -

0

probe type
0 = PTC
1 = NTC

P1

0

1

- - - -

1

°C decimal point
1 = yes

P2

0

1

- - - -

0

temperature unit of measurement (2)
0 = °C
1 = °F

P3

0

1

- - - -

1

enabling the needle probe
1 = yes

P4

0

1

- - - -

1

enabling the evaporator probe
1 = yes

P8 0 250 ds

5

delay displaying temperature variation detected by the
probes

P9

0

2

- - - -

1

type of backlight
0 = off during “on” status and during the “run” status

and with START/STOP key low light intensity during
the “stand-by” status

1 = with low light intensity during the “on” status and

during the "run" status and with START/STOP key
low light intensity during the “stand-by” status

2 = with high light intensity during the “on” status and

during the "run" status and with START/STOP key
high light intensity during the “stand-by” status

Par.

Min.

Max.

Unit

Default

Main regulator

r0

0.1

15.0

°C/°F (1)

2.0

parameters differential r7, r8, r9, r10, r11 and r12

r1

1

500

min

90

duration of time-controlled blast chilling

r2

1

500

min

240

duration of time-controlled deep freezing

r3 -50.0 99.0 °C/°F

(1)

3.0

temperature-controlled blast chilling end time temperature;
also end temperature of the temperature-controlled soft
deep freezing phase (temperature detected by the needle
probe); see also parameter r5

r4 -50.0 99.0 °C/°F

(1) -18.0

temperature-controlled deep freezing end temperature
(temperature detected by the needle probe); see also
parameter r6