11
ALARMS
11.1
Alarms
The following table illustrates the meaning of the alarm codes.
Code
Meaning
tiME
Temperature-controlled blast chilling or deep freezing not concluded within maximum duration alarm
(HACCP alarm).
Solutions:
-
check the value of parameters r5 and r6 and AA.
Main consequences:
-
the device will memorise the alarm.
AL
Minimum temperature alarm.
Solutions:
-
check the temperature of the cabinet
-
check the value of parameters A1 and A2.
Main consequences:
-
the device will continue to operate normally.
AH
Maximum temperature alarm (HACCP alarm).
Solutions:
-
check the temperature of the cabinet
-
check the value of parameters A4 and A5.
Main consequences:
-
the device will memorise the alarm.
id
Door open alarm
Solutions:
-
check the door conditions
-
check the value of parameters i0 and i1.
Main consequences:
-
the effect established with parameter i0.
HP
High pressure alarm.
Solutions:
-
check the conditions of the high pressure input
-
check the value of parameters i5 and i6.
Main consequences:
-
the effect established with parameter i5.
PF
Power supply cut-off alarm (HACCP).
Solutions:
-
check the device-power supply connection
-
check the value of the parameter A10.
Main consequences:
-
the device will memorise the alarm.