beautypg.com

11 alarms, 1 alarms – EVCO EVF815P9 User Manual

Page 44

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 44 of 60

11

ALARMS

11.1

Alarms

The following table illustrates the meaning of the alarm codes.

Code

Meaning

tiME

Temperature-controlled blast chilling or deep freezing not concluded within maximum duration alarm
(HACCP alarm).
Solutions:
-

check the value of parameters r5 and r6 and AA.

Main consequences:
-

the device will memorise the alarm.

AL

Minimum temperature alarm.
Solutions:
-

check the temperature of the cabinet

-

check the value of parameters A1 and A2.

Main consequences:
-

the device will continue to operate normally.

AH

Maximum temperature alarm (HACCP alarm).
Solutions:
-

check the temperature of the cabinet

-

check the value of parameters A4 and A5.

Main consequences:
-

the device will memorise the alarm.

id

Door open alarm
Solutions:
-

check the door conditions

-

check the value of parameters i0 and i1.

Main consequences:
-

the effect established with parameter i0.

HP

High pressure alarm.
Solutions:
-

check the conditions of the high pressure input

-

check the value of parameters i5 and i6.

Main consequences:
-

the effect established with parameter i5.

PF

Power supply cut-off alarm (HACCP).
Solutions:
-

check the device-power supply connection

-

check the value of the parameter A10.

Main consequences:
-

the device will memorise the alarm.