beautypg.com

EVCO EVF815P9 User Manual

Page 42

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 42 of 60

Defrosting LED.
If it is on:
-

defrosting will be in progress.

Pre-cooling LED.
If it is on:
-

pre-cooling will be in progress and the cabinet temperature will have reached that established
using parameter r12.

If flashing:
-

pre-cooling will be in progress and the cabinet temperature will not have reached that
established using parameter r12.

AUX

Auxiliary LED.
If it is on:
-

the cabinet light will be on

-

needle probe heating will be in progress

-

the UV light will be on

HACCP

HACCP LED.
If it is on:
-

all information regarding HACCP alarms will not have been displayed.

If flashing:
-

the device will have memorised at least one new HACCP alarm.

°C

Degree Celsius LED.
If it is on:
-

the temperature unit of measurement will be the degree Celsius.

°F

Degree Fahrenheit LED.
If it is on:
-

the temperature unit of measurement will be the degree Fahrenheit.

min

minutes LED.
If it is on:
-

the time unit of measurement will be the minute.

On/stand-by LED.
If it is on:
-

the device will be in the “stand-by” status.


If the START / STOP button flashes, it means an operating cycle is in progress.