EVCO EVF815P9 User Manual
Page 39
EVCO S.p.A.
EVF815 | Installer manual ver. 1.2 | Code 144F815E124
page 39 of 60
i6
0
1
- - - -
0
type of high pressure input 1
0 = normally open (input active with closed contact)
1 = normally closed (input active with open contact)
i7 -1 240
s
5
high pressure alarm signalling delay (“HP” code)
-1 = the alarm will not be signalled
Par.
Min.
Max.
Unit
Default
Digital outputs
u1
0
1
- - - -
0
utility managed by the output K4 (14)
0 = door heating elements (in this case, parameter u5
will assume significance)
1 = condenser fan (in this case, parameter u5 will
assume significance)
u2
0
1
- - - -
0
enabling of cabinet light switch-on/off in manual mode
during "stand-by" status (15)
1 = yes
u5 -50.0 99.0 °C/°F
(1) 20.0
cabinet temperature over which the door heating elements
are off (4)
u6 1 240 min
5
if parameter u11 is set at 1, maximum duration of needle
probe heating; see also parameter u7
if parameter u11 is set at 2, duration of UV light switch-on
for the sterilisation cycle
u7 -50.0 99.0 °C/°F
(1) 40.0
needle probe heating end temperature (temperature
detected by the needle probe); see also parameter u6
u11
0
2
- - - -
0
utility managed by the output K5 (14)
0 = cabinet light (in this case, the DEEP FREEZING key
and parameters i0 and u2 will assume significance)
1 = needle probe heating (in this case, the DEEP
FREEZING key and parameters u6 and u7 will
assume significance)
2 = UV light (in this case, the DEEP FREEZING key and
parameter u6 will assume significance)
Par.
Min.
Max.
Unit
Default
Serial communication (MODBUS)
LA
1
247
- - - -
247
device address