EVCO EVF815P9 User Manual
Page 34
EVCO S.p.A.
EVF815 | Installer manual ver. 1.2 | Code 144F815E124
page 34 of 60
C0 0 240 min
0
minimum time between restoring the power supply after a
power cut, occurring during an operating cycle and
compressor switch-on
C1 0 240 min
5
minimum time between two consecutive compressor switch-
ons (3)
C2 0 240 min
3
minimum time between compressor switch-off and
successive switch-on (3)
C3
0
240
s
0
compressor switch-on minimum duration
C4 0 240 min
10
duration of compressor switch-off during the cabinet probe
error (“Pr1” code) that occurs during storage; see also
parameter C5
C5 0 240 min
10
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post blast chilling
storage; see also parameter C4
C9 0 240 min
30
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post deep freezing
storage; see also parameter C4
Par.
Min.
Max.
Unit
Default
Defrosting (5)
d0 0 99
h
8
defrosting interval (6)
0 = defrosting will never be activated at intervals