EVCO EVF815P9 User Manual

Page 34

background image

EVCO S.p.A.

EVF815 | Installer manual ver. 1.2 | Code 144F815E124

page 34 of 60

C0 0 240 min

0

minimum time between restoring the power supply after a
power cut, occurring during an operating cycle and
compressor switch-on

C1 0 240 min

5

minimum time between two consecutive compressor switch-
ons (3)

C2 0 240 min

3

minimum time between compressor switch-off and
successive switch-on (3)

C3

0

240

s

0

compressor switch-on minimum duration

C4 0 240 min

10

duration of compressor switch-off during the cabinet probe
error (“Pr1” code) that occurs during storage; see also
parameter C5

C5 0 240 min

10

duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post blast chilling
storage; see also parameter C4

C9 0 240 min

30

duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post deep freezing
storage; see also parameter C4

Par.

Min.

Max.

Unit

Default

Defrosting (5)

d0 0 99

h

8

defrosting interval (6)
0 = defrosting will never be activated at intervals