EVF815 | Installer manual ver. 1.2 | Code 144F815E124
page 14 of 60
4.1.1
Connection of the terminating resistors
The terminating resistor must be connected in order to reduce the reflections on the signal transmitted along the
cables that connect the user interface to the control model.
To connect the terminating resistors, position the jumper as illustrated in the following drawing.
To disconnect the terminating resistors, position the jumper as illustrated in the following drawing.
4.2
Warnings for the electric connection
-
do not use electric or pneumatic screwdrivers on the device terminal board
-
if the device has been taken from a cold to hot place, humidity could condense inside; wait about 1 hour before
powering it
-
make sure that the power supply voltage, the frequency and the operational electric power of the device,
correspond with those of the local power supply; see chapter 14 "TECHNICAL DATA"
-
disconnect the device power supply before proceeding with any type of maintenance
-
do not use this device as a safety device
-
for repairs and information regarding the device, contact the EVCO sales network.