Establishing a Telnet Connection

Establishing a Telnet Connection

Use the following procedure to telnet to the DeviceMaster LT.

1.

Open a telnet session, enter the DeviceMaster LT IP address. If using
Windows, open a Command window and type telnet [ip_address]

2.

Press the Enter key if you did not program a password or type the password
and press Enter.

Note: The DeviceMaster LT does not come pre-programmed with a password.

3.

Type reset, and close the session.

4.

Open a new telnet session, enter the DeviceMaster LT IP address, and the
password.

5.

Type dis to disable the Bootloader.

6.

Verify that the system responds with a Loading disabled message.

♥♦

Password:

Comtrol DeviceMaster RTS Model ID: 5002535

SocketServer 9.18
Built: Wed Aug 28 11:08:48 CST 2013
IP Addr: 192.168.11.52, Mask: 255.255.0.0, Gateway: 192.168.0.254
MAC Addr: 00:c0:4e:29:ff:f5

dm> reset

*********************************************
**
** Comtrol DeviceMaster Bootloader Version 3.23
** RedBoot(tm) environment - built 14:59:20, Oct 13 2011
** Platform: Comtrol DeviceMaster (ARM 7TDMI)
** Portions Copyright (C) 2000. Red Hat, Inc.
** Portions Copyright (C) 2001-2008 Comtrol Corp.
*********************************************

FLASH: 64 blocks of 65536 bytes each
FLASH: 4194304 bytes (0x05000000 - 0x05400000)
RAM: 8126464 bytes (0x00000000 - 0x007c0000)
RedBoot> dis
Loading disabled
RedBoot> _