beautypg.com

3 explicit messaging, Comm un ica ti ng wit h th e ib ser ies – KEYENCE DL-DN1 User Manual

Page 60

background image

3-3 Explicit Messaging

3-32

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

3

Comm

un
ica
ti

ng wit

h th

e

IB

Ser

ies

Nx10+3

64

Group-3 entry count

R

20

65

Key lock setting

R/W

0

0: Release
1: Key lock

66

BANK setting

*14

R/W

0

0: Switched to Bank 0
1: Switched to Bank 1
2: Switched to Bank 2
3: Switched to Bank 3

67

Timing input

*15

R/W

0

0: Timing input OFF
1: Timing input ON

68

Laser emission stop input

*15

R/W

0

0: Laser emission stop input OFF
1: Laser emission stop input ON

69 to

6B

Reserved

6C

Sub display's screen

R/W

0

0: R.V. value display screen
1: Analog output value screen
2: HIGH setting value screen
3: LOW setting value screen
4: Shift target setting screen

6D

System parameter

*12

R/W

0

Main unit: 0 - 9
Expansion unit: 0 - 1

6E

Tolerance tuning setting width

*16

R/W

10.00 0.00 to 999.99

6F

Calibration function

R/W

0

0: No correction (Default)
1: Measured correction
2: Logical correction

70

Measured/Logical correction target 1

*7

R/W

0.00 -999.99 to +999.99

71

Measured/Logical correction target 2

*7

R/W

100.00 -999.99 to +999.99

72 to

76

Reserved

77

Logical correction measured 1

*7

R/W

0.00 -999.99 to +999.99

78

Logical correction measured 2

*7

R/W

100.00 -999.99 to +999.99

79 to

83

Reserved

Nx10+4

64

Group-4 entry count

R

30

65

Reserved

66

Measurement mode

R/W

0

0: Percent mode
1: Dimension mode

67

Received/Blocked light mode

R/W

0

0: Received light mode
1: Blocked light mode

68

Reserved

InstID
(DEC)

AttrID

(HEX)

Name

Description Attribute

Default

value

Parameter range