- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3-2
I/O Communication
The device map varies depending on the operating mode of the DL-DN1. Select an
operating mode suited for the functions of the sensor amplifiers to be used, before
accessing each device.
The memory in the DeviceNet master unit is linked to the buffer memory in the DL-
DN1 as shown below.
Select the DL-DN1 operating mode to suit the functions of the sensor amplifiers to be
used.
The DeviceNet device configuration and the data available for I/O communication
vary, depending on the selected operating mode of the DL-DN1 and the number of
connected sensor amplifiers. An appropriate operating mode should be determined
by considering the memory occupied and the data that can be communicated.
Output data
Data here will be
reflected in the master unit.
Input data
Data here has been
output from the master unit.
DeviceNet master unit
DL-DN1
Sensor amplifier
IN area
OUT area
I/O communication
I/O communication
Selecting the DL-DN1 Operating Mode
Available function of sensor
amplifier
Operating mode of DL-DN1
De
vi
ce
map
s
Co
m
m
u
ni
cat
ion
me
tho
d
3-output
3-output + current value
5-output
5-output + current value
-
3-input
-
3-input
-
5-input
-
5-input
-
BA
NK
Set
ting
va
lu
e
-
BA
NK
Set
ting
va
lu
e
-
BA
NK
Set
ting
va
lu
e
-
BA
NK
Set
ting
va
lu
e
Read status
Yes
Yes
Yes
Yes
Read outputs
1 - 5
HIGH
LOW
GO
Check output
No
No
(Not used)
Read comparator value (PV value)
No
Yes
No
Yes
External
inputs
1 - 5
External input 1
No
Yes
No
Yes
No
Yes
No
Yes
External input 2
External input 3
External input 4
No
No
(Not used)
Change BANK number
No
Yes No
No
Yes No
No
Yes No
No
Rewrite setting value
No Yes
No Yes
No Yes