beautypg.com

Run circuit, 2000 series tractors, Figure 7.20 – Cub Cadet 2000 Series User Manual

Page 112

background image

2000 Series Tractors

106

Run Circuit

With the key switch in the RUN position, the A1 termi-

nal sends power to:

the afterfire solenoid

the windings of the PTO relay

the PTO switch C-COM terminal

the RMC module “A1 pwr” terminal

the headlights

the system monitor

See Figure 7.20.

This is identical to what happens with the key in the
START position, except that the circuit that actually spins
the starter motor is not energized.

2-#

3EAT

237

'RND

!

!

%04/

h/Nv

'

!

,

3

!

-

"

+EY

"ATTERY

.%'

0/3

&USE

'RND

'ROUND

'ROUND

h!RMED

04/

#/
-

./

.#

3YSTEM

-ONITOR

(EADLIGHTS

04/

!T

!FTERFIRE

3OLENOID

'ROUND

!

"

#

6WDUWHU0RWRU

*URXQG

6ROHQRLG

Figure 7.20