Compaq 21264 User Manual
Page 75
![background image](/manuals/64191/75/background.png)
Alpha 21264/EV67 Hardware Reference Manual
Hardware Interface
3–7
21264/EV67 Signal Names and Functions
BcVref
I_DC_REF
1
Tag data input reference voltage.
SysVref Domain
SysAddIn_L[14:0]
I_DA
15
Time-multiplexed SysAddIn, system-to-21264/EV67.
SysAddInClk_L
I_DA
1
Single-ended forwarded clock from system for
SysAddIn_L[14:0] and SysFillValid_L.
SysAddOut_L[14:0]
O_OD
15
Time-multiplexed SysAddOut, 21264/EV67-to-system.
SysAddOutClk_L
O_OD
1
Single-ended forwarded-clock.
SysCheck_L[7:0]
B_DA_OD
8
Quadword ECC check bits for SysData_L[63:0].
SysData_L[63:0]
B_DA_OD
64
Data bus for memory and I/O data.
SysDataInClk_H[7:0]
I_DA
8
Single-ended system-generated clocks for clock forwarded
input system data.
SysDataInValid_L
I_DA
1
When asserted, marks a valid data cycle for data transfers to
the 21264/EV67.
SysDataOutClk_L[7:0] O_OD
8
Single-ended 21264/EV67-generated clocks for clock for-
warded output system data.
SysDataOutValid_L
I_DA
1
When asserted, marks a valid data cycle for data transfers
from the 21264/EV67.
SysFillValid_L
I_DA
1
Validation for fill given in previous SysDC command.
SysVref
I_DC_REF
1
System interface reference voltage.
Clocks and PLL
ClkIn_H
ClkIn_L
I_DA_CLK
2
Differential input signals provided by the system.
EV6Clk_H
EV6Clk_L
O_PP_CLK
2
Provides an external test point to measure phase alignment of
the PLL.
FrameClk_H
FrameClk_L
I_DA_CLK
2
A skew-controlled differential 50% duty cycle copy of the
system clock. It is used by the 21264/EV67 as a reference, or
framing, clock.
PLL_VDD
3.3 V
1
3.3-V dedicated power supply for the 21264/EV67 PLL.
MiscVref Domain
ClkFwdRst_H
I_DA
1
Systems assert this synchronous signal to wake up a powered-
down 21264/EV67. The ClkFwdRst_H signal is clocked into
a 21264/EV67 register by the captured FrameClk_x signals.
DCOK_H
I_DA
1
dc voltage OK. Must be deasserted until dc voltage reaches
proper operating level. After that, DCOK_H is asserted.
IRQ_H[5:0]
I_DA
6
These six interrupt signal lines may be asserted by the system.
MiscVref
I_DC_REF
1
Reference voltage for miscellaneous pins.
PllBypass_H
I_DA
1
When asserted, this signal will cause the input clocks
(ClkIn_x) to be applied to the 21264/EV67 internal circuits,
instead of the 21264/EV67’s global clock (GCLK).
Table 3–3 21264/EV67 Signal Descriptions by Function (Continued)
Signal
Type
Count
Description