Alpha 21264/EV67 Hardware Reference Manual

Hardware Interface

3–7

21264/EV67 Signal Names and Functions

BcVref

I_DC_REF

1

Tag data input reference voltage.

SysVref Domain

SysAddIn_L[14:0]

I_DA

15

Time-multiplexed SysAddIn, system-to-21264/EV67.

SysAddInClk_L

I_DA

1

Single-ended forwarded clock from system for
SysAddIn_L[14:0] and SysFillValid_L.

SysAddOut_L[14:0]

O_OD

15

Time-multiplexed SysAddOut, 21264/EV67-to-system.

SysAddOutClk_L

O_OD

1

Single-ended forwarded-clock.

SysCheck_L[7:0]

B_DA_OD

8

Quadword ECC check bits for SysData_L[63:0].

SysData_L[63:0]

B_DA_OD

64

Data bus for memory and I/O data.

SysDataInClk_H[7:0]

I_DA

8

Single-ended system-generated clocks for clock forwarded
input system data.

SysDataInValid_L

I_DA

1

When asserted, marks a valid data cycle for data transfers to
the 21264/EV67.

SysDataOutClk_L[7:0] O_OD

8

Single-ended 21264/EV67-generated clocks for clock for-
warded output system data.

SysDataOutValid_L

I_DA

1

When asserted, marks a valid data cycle for data transfers
from the 21264/EV67.

SysFillValid_L

I_DA

1

Validation for fill given in previous SysDC command.

SysVref

I_DC_REF

1

System interface reference voltage.

Clocks and PLL

ClkIn_H
ClkIn_L

I_DA_CLK

2

Differential input signals provided by the system.

EV6Clk_H
EV6Clk_L

O_PP_CLK

2

Provides an external test point to measure phase alignment of
the PLL.

FrameClk_H
FrameClk_L

I_DA_CLK

2

A skew-controlled differential 50% duty cycle copy of the
system clock. It is used by the 21264/EV67 as a reference, or
framing, clock.

PLL_VDD

3.3 V

1

3.3-V dedicated power supply for the 21264/EV67 PLL.

MiscVref Domain

ClkFwdRst_H

I_DA

1

Systems assert this synchronous signal to wake up a powered-
down 21264/EV67. The ClkFwdRst_H signal is clocked into
a 21264/EV67 register by the captured FrameClk_x signals.

DCOK_H

I_DA

1

dc voltage OK. Must be deasserted until dc voltage reaches
proper operating level. After that, DCOK_H is asserted.

IRQ_H[5:0]

I_DA

6

These six interrupt signal lines may be asserted by the system.

MiscVref

I_DC_REF

1

Reference voltage for miscellaneous pins.

PllBypass_H

I_DA

1

When asserted, this signal will cause the input clocks
(ClkIn_x) to be applied to the 21264/EV67 internal circuits,
instead of the 21264/EV67’s global clock (GCLK).

Table 3–3 21264/EV67 Signal Descriptions by Function (Continued)

Signal

Type

Count

Description