Counterpart User Manual
6.1.2
ID Commands
Up to 150 codes can be entered under ID commands.
Table 6-2. ID Commands
6.1.3
Reporting Commands
Reporting commands send specific information to the
serial port. The commands listed in Table 6-3 can be
used in all modes.
Transmitting all configuration settings can be
achieved by the DUMPALL command
6.1.4
Clear and Reset Commands
The following commands can be used to clear and
reset the
Counterpart
:
RS
: Reset system. Resets the indicator without
resetting the configuration.
RESETCONFIGURATION
: Restores all
configuration parameters to their default values
(menu mode only). The
RESETCONFIGURATION
function can also be initiated by pre ssing
navigating to the
DEFALT
parameter under the
VERS menu and selecting YES. Then press
ENTER
to reset the indicator.
All load cell calibration settings are lost
w h e n t h e R E S E T C O N F I G U R AT I O N
command is run.
CLEARBUFFER
: Clears the Weighvault data buffer.
Command
Function
ID.CODE#n
ID code
ID.DESC#n
item description
ID.LOCATION#n
item stock location
ID.LOT#n
lot number
ID.PARTNUMBER#n
part number
ID.QUANTITY#n
inventory quantity
ID.TARE#n
tare weight value
ID.UNITS#n
units for tare and unit weight values
ID.UNITWEIGHT#n
unit weight value
ID.CLRALL
clear all IDs from memory
Note: The ID.CLRALL command only
works in setup mode
ID.CLEAR.INDEX#n
clear ID at index n from memory
ID.CLEAR.CODE#n
clear ID with code of n from memory
Command
Function
DUMPALL
List all parameter values, ID information
and setpoint data
DUMPCONFIG
List all parameter values excluding ID
information and setpoint data
DUMPAUDIT
List audit trail information
DUMPBUFFER
Lists Weighvault buffer information
DUMPIDS
List all ID information
DUMPID.INDEX
List a specific ID by index. See table 6-13
for more information.
DUMPIDCODE
List a specific ID by code. See table 6-13
for more information.
VERSION
Write
Counterpart
software version
P
Write current displayed weight with units
identifier. See Section 9.2.1 on page 79.
XE
Returns a 10-digit code representing any
error conditions currently shown on the
front panel.
ADCS
Return number of A/Ds installed
Table 6-3. Reporting Commands