beautypg.com

2 scale 3 submenu, Scale 3 submenu, Table 3-4. scale three submenu parameters – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.2 User Manual

Page 33: Counterpart user manual - configuration 27

background image

Counterpart User Manual - Configuration

27

3.6.2

SCALE 3 Submenu

Figure 3-7. Scale 3 Serial Menu

SCALE 3 Submenu

Parameter

Choices

Description

Format Submenu

PRIMRY

UNITS
DECPNT
DSPDIV

Allows you to set the primary units, decimal point format, and display divisions.

SEC

KG
G
LB
OZ
OFF

Allows you to set the secondary units.

Decimal point format and display divisions are selected automatically. Values are
kg=kilogram (default); g=gram; lb=pound; oz=ounce; and off.

If using the token and secondary or tertiary values are changed,
the stream tokens must be changed to match in order to stream
secondary or tertiary.

TER

OFF
KG
G
LB
OZ

Allows you to set the tertiary units.

Decimal point format and display divisions are selected automatically. Values are off
(default); kg=kilogram; g=gram; lb=pound; oz=ounce.

If using the token and secondary or tertiary values are changed,
the stream tokens must be changed to match in order to stream
secondary or tertiary.

Accum Submenu

Table 3-4. Scale Three Submenu Parameters

FEATUR

PFORMT

SERIAL

XXXXXXX

ID

DISPLAY

TEST

SETUP

AUDIT

CALIBR

SCALES

FORMAT

ACCUM

OFF

ON

SEC

UNITS

DECPNT

DSPDIV

TER

PRIMRY

LB/OZ *

LB

G

OZ

KG

LB/OZ *

KG

OZ

G

LB

G

OFF

KG

LB

OZ

8888800

1D

5D

2D

8888880

8888888

8.888888

88.88888

888.8888

8888.888

OFF

CONFIG

SCALE 1

SCALE 2

SCALE 3

ETHERNET

OFF

Scale Parameter Levels

Level 1

Level 2

Level 3

**Scale 3 sub-menu appears only when

serial port 1 is set to SCALE or IND SCALE.

88888.88

888888.8

SETPTS

DIGIO

VERS

SETPTS

Note

Note