Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.2 User Manual
Page 49
Counterpart User Manual - Configuration
43
BATCH
Off
On
Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint.
PSHACCM
Off
On
ONquiet
Specifiy ON to update the accumulator and perform a print operatoin when the setpoint is
satisfied. Specify ONQUIET to update the accumulator without printing.
PSHPRNT
Off
On
Waitss
Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS to
wait for standstill after setpoint is satisfied before printing.
PSHTARE
Off
On
Specify ON to perform an acquire tare operation when the setpoint is satisfied. Note that
PSHTARE acquires the tare regardless of the value specified for the REGULAT parameter
on the FEATURE menu.
ACCESS
On
Hide
Off
Specifies the access allowed to setpoing parameters shown by pressing the Setpoint
softkey in normal mode.
ON: Values can be displayed and changed.
HIDE: Values cannot be displayed or changed.
OFF: Values can be displayed but not changed.
DIGOUT
None
1-4
Lists all digital output bits available. This parameter is used to specify the digital output bit
associated with this setpoint. Use the DIGI/O menu to assign bit function to OUTPUT. For
continuous setpoints, the digital output becomes active (low) when the condition is met;
for batch setpoints, the digital output is active until the setpoint condition is met.
SENSE
Normal
Invert
Specifies whether the value of the digital output associated with this setpoint is inverted
when the setpoint is satisified.
Table 3-8. Setpoints Menu Parameters