5 ids, 1 setting an id using the normal mode, Setting an id using the normal mode – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.2 User Manual
Page 61: Key after removing each batch of pieces, Press the
Counterpart User Manual - Scale Operations
55
Counting Out of a Full Container - See Total Amount Remaining in the Container
To carry out this operation you must know the tare weight ahead of time.
1. Place the full container on the scale. Press the
TARE
key.
2. Remove a 10 piece sample to the container and press the
SAMPLE
key. After the unit weight has been
calculated, return the 10 piece sample to the container.
3. If you want to see how many are still in the bin you first have to know the tare weight of the bin or
container. After removing the parts you want to take out of the bin, simply digitally enter the tare weight
of the bin and press the
TARE
key. The scale will display how many parts were left in the bin. To print a
label to put on the bin showing the total quantity in the bin, press the
key.
Negative Counting - Total Removed Displayed at the End
With this procedure you can count accurately out of a full container for kitting, shipping, etc.without having to
know the tare weight of the container.
1. Place a full container on the scale and press
TARE
.
2. Remove a 10 piece sample from the container and press
SAMPLE
. After the unit weight has been
calculated, return the 10 piece sample to the container.
3. Remove the number of pieces you need for kitting, shipping, etc. The amount removed will be displayed.
If you need a label for each kit or container, press the
key after removing each batch of pieces.
5.5
IDs
IDs are used to save and recall previously set codes, descriptions, unit weight, and tare preferences. The
Counterpart
has the capacity to store up to 150 individual IDs. There are three ways that IDs can be entered and
set. Those three ways include:
1. Normal
2. Through Count Mode
3. Through Revolution
To enter alpha ID characters you can double press the numeric keypad to obtain alpha characters much like
accessing alpha characters on a cell phone keypad.
To store more than 150 IDs, WeighVault is required (see Section 5.6 on page 58).
Figure 5-1. ID Menu
5.5.1
Setting an ID Using the Normal Mode
1. Press the
MENU SETUP
key
to access this menu.
2. Press to ID and then press
and you will be at REG1.
3. Navigate to the REG number you want to set (1-150) by using the and keys.
All menus have wrap-around functionality. If you are at ID1 and want to access ID150, you can quickly do so
by moving backwards through the menu.
REG 1
REG 2
QUANTITY
SAME AS REG 1
CODE
DESC
PART NUM
LOT
UNIT WT
TARE
VALUE
VALUE
VALUE
LB
G
KG
OZ
OFF
UNITS
LOCATION
XXXXXXX
ID
DISPLAY
TEST
SETUP
AUDIT
CALIBR
REG 150
SAME AS REG 1
VALUE
VALUE
VALUE
VALUE
VALUE
SETPTS
MENU
SETUP
Note