Installation/Operation Manual - Appendix
83
10.17 Adding Counter and Position Indicators
6HULHV
$GGLQJ FRXQWHU DQG
SRVLWLRQ LQGLFDWRU
Type series 521
npn: switching to 0 V
pnp: switching to
+V(4-30)
4.1 Input polarity
4.2 Activating the 30 Hz filter
max. count frequency
10 kHz
max. count frequency
30 Hz
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with
pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Count input and count
direction input
INP A: count input
INP B: count direction input
4.3 Input mode
Differential input
INP A: count input adding
INP B: count input subtracting
4.4 Scaling factor (Multiplier)
Factor can be set from
00.0001 up to 99.9999. The
decimal point is fixed “0“
won’t be accepted!
KESSLER-ELLIS PRODUCTS
KESSLER-ELLIS PRODUCTS
KESSLER-ELLIS PRODUCTS
KESSLER-ELLIS PRODUCTS
KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724
Toll Free:800-631-2165 • Fax:732-935-9344
99631 4/9/98
3. Setting of the operatingparameters
a.
Hold down keys on front panel and switch on the
supply voltage.
b.
The display shows
c.
After releasing the keys the display alternates
between menu title and corresponding menu item at
a frequency of 0.5 Hz. After any key is pressed down,
only the menu item is displayed.
d.
Pressing the right key, the menu item will be
switched to next value.
e.
Hold down the left key and press the right key to
enter and switch to the next menu title.
f.
After programming the last menu item, the
programming routine will be left and the new values
will be stored by switching the menu item to „YES“. If
you chose „NO“, the programming routine will be
passed through once again.
4. Programming routine
Programmable parameters are shown in succession. After
one pass, the device is fully programmed.
In each case the first shown item is the factory preset.
1. Description
•
6digit adding counter, resetable
•
LED-Display with 8 mm high characters and very
high luminosity
•
Display range -199999..999999 (overflow condition
will be indicated by flashing of the display)
•
Programming of count functions and operating
parameters via the setting keys. During programming
the display guides the user with text prompts.
•
Optocoupler output (as option). Active at count
values <
0.
•
Programmable features:
Input polarity (npn or pnp)
Max. count frequency (30 Hz or 10 kHz)
Input mode
Decimal point
Scaling factor
Reset mode:
electrical
manual
manual and electrical
no reset
Set value (Goes to selected
value at reset.)
2. Inputs
INP A
Dynamic count input. Max. count frequency 30 Hz or
10 kHz programmable via set up
INP B
Dynamic count input. Max. count frequency 30 Hz or
10 kHz programmable via set up
RESET
Dynamic reset input. Linked to the red reset key.
3. Optocoupler Output
Active if count value < 0. Simple preset counter can be
realized, when using subtract mode.