2 preacts - decumulative scale, 3 ez change criticals - material preacts, 4 entering a mix design – Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual
Page 67: Preacts - decumulative scale, Ez change criticals - material preacts

Installation/Operation Manual - Appendix
63
10.3.2
Preacts - Decumulative Scale
Admin menu
Data bases
Scales
(Desired scale)
SCALE TYPE = DECUMULATIVE
10.3.3
EZ Change Criticals - Material Preacts
One of the soft keys available when the display shows the scale weights is EZ change criticals. When this softkey
is pressed, a material preact softkey is one of the new selections on the bottom of the screen. When this key is
pressed and a material preact value is changed, keep in mind that all of the 10 preact levels will be modified to
the new value. This may be beneficial when working with a decumulative scale but catastrophic working with a
hopper scale.
10.3.4
Preact Value Level When Used in Lose in Weight (LIW)
Admin Menu
Databases
Scales
Aggregate
Preacts
LEVEL 1 PREACT IS THE ONLY PREACT LEVEL USED IN LIW
10.4 Entering a Mix Design
Use the following steps to enter a mix design.
1. Press the Admin softkey.
2. Arrow down to the Databases.
3. Arrow right to enter Databases.
4. Arrow down to Mixes.
5. Arrow right to enter Mixes.
You should see a list of designs already programmed in the CB-2. At this point you should be able to choose from
the following softkeys.
•
Add - Press the Add softkey to add a new mix design. With this choice you will need to add individual
ingredients to create a completely new mix.
•
Copy - Choose a mix that has all the ingredients you need and press Copy. You can edit the mix
ingredient values to make a new mix.
•
Change - Press the Change softkey to edit an ingredient of a mix.
•
Delete - Press the Delete softkey to remove a mix design.
•
Exit - Press the Exit softkey to exit and return to the previous screen.